Infrared Building Survey, near Glasgow

House front elevation
Dunboig Exterior

Project Description

AiroTech carried out an infrared thermography building survey on this newly constructed two storey 3 bedroom house near Glasgow, Scotland. The owners experience cold areas within the house, up to 100C temperature difference between the lounge and entrance hall. In addition the owners have had far higher than expected energy bills last winter (2019/20), to compensate for heat losses within the property.

AiroTech installed a calibrated test fan in the backdoor opening of the property then proceeded to depressurise the house to -50pa. A calibrated high resolution infrared camera was then used to establish the overall building condition and identify any localised cold spots/thermal anomalies.

A significant number of areas of uncontrolled air infiltration were identified within the house; these included:

  • Window frames\sashes, below some sills and window trickle vents (in the closed positions)
  • Mechanical extractor fans (turned off)
  • Back and front doors
  • Patio doors
  • Loft access hatch]

Convection losses were also observed in the first-floor bedrooms, dining room and en-suite bathroom. Areas of insulation inconsistencies were recorded.

For a free infrared thermographic building survey quote please contact us.

Project Details

  • Infrared Building Survey

  • Near Glasgow, Scotland

  • New build two storey 3 bedroom house

  • Private house owners

  • October 2020

Contact Us

Needing Infrared Thermography?

If you require Infrared Thermography for your Commercial or Residential property, please contact AiroTech for a quotation or to discuss your requirements.